Seismic Tested Products

As a pioneering manufacturer of curtain wall systems, we invest in the most up-to-date seismic testing to industry standards. The AAMA 501.6 test determines the horizontal racking displacement amplitude of the exterior wall system that would cause glass fallout within a controlled environment. 
Clear All
Product
Performance/Features
Thermal Performance
Seismic Tested
Hurricane Resistance
Blast Mitigation
Dimensions
Sightline
Application Height
System Depth
Glazing
Glazing Method
Glass Plane
Glazing Installation
Glazing Infill
View

1600 Wall System®1 Curtain Wall
  • 2-1/2″ (63.5mm) sightline
  • 6″ (152.4mm), 7-1/2″ (190.5mm) or 10-1/2″ (267mm) depth
  • Thermal performance
  • Seismic (AAMA 501.4 and 501.6 standards)
  • Low- to mid-rise applications
  • Blast mitigation, hurricane resistance
  • test

1600UT System™1 Curtain Wall
  • 2-1/2″ (63.5mm) sightline
  • 6″ (152.4mm), 7-1/2″ (190.5mm) or 10-1/2″ (266.7mm) system depth with 1” double-pane infill
  • 6-3/4″ (171.5mm), 8-1/4″ (209.6mm) or 11-1/4″ (285.8mm) system depth for triple-pane 1-3/4″ (44.5mm) infill
  • Seismic (AAMA 501.4 and 501.6 standards)
  • Blast mitigation, storm shelter (ICC 500)

1600UT System™2 Curtain Wall
  •  2-1/2″ (63.5mm) sightline
  • 6″ (152.4mm), 7-1/2″ (190.5mm) or 10-1/2″ (266.7mm) system depth with 1” double-pane infill
  • 6-3/4″ (171.5mm), 8-1/4″ (209.6mm) or 11-1/4″ (285.8mm) system depth for triple-pane 1-3/4″ (44.5mm) infill
  • Ultra-thermal performance
  • Seismic (AAMA 501.4 and 501.6 standards)
  • Vertical Structural Silicone Glazed (SSG)

1600 SS Curtain Wall System
  • 1600 SS has 2-1/2″ (63.5mm) sightlines
  • Standard 6″ (152.4mm) or 7-1/2″ (190.5mm) depth
  • Infill options up to 1-1/8″ (28.6mm)
  • A pre-glazed option (unitized curtain wall)
  • Blast mitigation
  • Seismic (AAMA 501.4 standards)

1600 Wall System®2 Curtain Wall
  • 2-1/2″ (63.5mm) sightline
  • 6″ (152.4mm), 7-1/2″ (190.5mm) or 10-1/2″ (267mm) depth
  • Thermal performance
  • Low- to mid-rise applications
  • Seismic (AAMA 501.4 and 501.6 standards)
  • Vertical Structural Silicone Glazed (SSG), hurricane resistance

Clearwall® Curtain Wall System
  • 5/8″ (15.9mm) exterior weatherseal sightline
  • 2-1/2″ (63.5mm) interior metal sightline
  • Variable depth
  • High thermal performance
  • 4-sided toggle glazed
  • Hurricane resistance
  • Seismic (AAMA 501.4 and 501.6 standards)

2500 UT Unitwall® System
  • 2-1/2″ (63.5mm) sightline
  • Standard infill options: 1/4″ (6.4mm), 1″ (25.4mm) and 1-3/4″ (44.5mm)
  • 7-1/2″ (190.5) captured and 6-1/2″ (165.1mm) 4-sided SSG/SGT depth in 1″ (25.4mm) infill
  • 8-1/4″ (209.6) captured and 7-1/4″ (184.2mm) 4-sided SSG/SGT depth in 1-3/4″ (44.5mm) infill
  • Ultra-thermal performance
  • Mid- to high-rise applications
  • Seismic (AAMA 501.4 and 501.6 standards)

1600 Wall System®5 Curtain Wall
  • 2-1/2″ (63.5mm) sightline
  • 6″ (152.4mm) or 7-1/2″ (190.5mm) depth
  • Thermal performance
  • Low- to high-rise application
  • Seismic (AAMA 501.4 standards)
  • Vertical Structural Silicone Glazed (SSG) options
  • Ribbon window wall application option available